Dedicated Server Room
An isolated space fully controlled by the client. A turnkey engineering solution for scalable, enterprise-grade IT infrastructure.
A turnkey room. Fully yours.
Security perimeter
Dedicated, enterprise-grade infrastructure — from security and energy efficiency to customizable engineering systems.
High-level access
Access-controlled rooms, on-site workspaces for your team, flexible placement options.
Customized infrastructure
Cooling, access, monitoring, and fire-suppression systems tailored to your requirements.
Maximum reliability
Continuous equipment operation with redundant engineering systems.
Flexibility & scalability
Support for server cabinets of any type and size.
11 hectares.
Built for tomorrow's workloads.
The Akashi campus hosts data centers, office and warehouse facilities, plus EV charging stations. The infrastructure operates 24/7.
- Land area
- 11 hectares
- Built area
- 60,000 m² (4 DC buildings)
- Administrative building
- 6,000 m²
- IT load capacity
- 28 MW
- Raised floor height
- 1.6 m
- Floor load capacity
- 2 tons / m²
- Loading terminals
- Two with freight elevators
Innovative solutions for power, fuel, and security.
Power
- 2 independent power supply entries
- Active/active sources with 110 kV redundancy
- Dual electrical redundancy per building
- UPS with 5/4N redundancy, 10-min battery backup
Backup & fuel
- Backup generators — 12 hrs autonomy at full load
- 2 fuel suppliers, 4-hour delivery SLA
- Automatic failover and load-balancing
Fire & security
- Triple-layer fire detection with gas suppression
- Dual redundancy on all suppression systems
- Multi-perimeter access control, 24/7 CCTV
What clients ask us.
What is a dedicated server room at Akashi?
An isolated hall under full client control — a turnkey engineering solution for scalable, enterprise-grade IT infrastructure, not a shared cage or a single cabinet.
Which engineering systems can be customized?
Cooling, access control, monitoring, and fire suppression are tailored to the room. Power is delivered through two independent 110 kV feeds with UPS 5/4N redundancy and 12 hours of generator autonomy at full load.
Who is a private hall for?
Enterprises that need an isolated security perimeter, on-site workspace for their own engineers, and room to grow cabinets of any type and size — without sharing the hall.
Is 24/7 access and remote hands included?
Yes. Access-controlled rooms operate around the clock, and remote hands are available 24/7 for on-site technical operations.
When can a dedicated room go live?
First phase (DC-1) is scheduled to launch in May 2027. Pre-launch demand is already 107% of DC-1 capacity (5.54 MW reserved). Capacity is discussed individually.
We reply within one business day.
Questions about colocation, partnership, or the project? Reach out however suits you.