Private Cage
A dedicated section of the server room with enhanced perimeter security and customizable configurations tailored to your business.
A section of the DC that's only yours.
Security perimeter
Enhanced perimeter protection with customized access control and flexible configuration.
Stable operation
Uninterrupted performance of your IT infrastructure.
Dedicated power
Guaranteed power delivery tailored to the needs of your Cage.
Flexible deployment
Support for standard and non-standard server cabinets of any size.
Private access zone
Dedicated, isolated section accessible only to your authorized personnel. 24/7.
11 hectares.
Built for tomorrow's workloads.
The Akashi campus hosts data centers, office and warehouse facilities, plus EV charging stations. The infrastructure operates 24/7.
- Land area
- 11 hectares
- Built area
- 60,000 m² (4 DC buildings)
- Administrative building
- 6,000 m²
- IT load capacity
- 28 MW
- Raised floor height
- 1.6 m
- Floor load capacity
- 2 tons / m²
- Loading terminals
- Two with freight elevators
Innovative solutions for power, fuel, and security.
Power
- 2 independent power supply entries
- Active/active sources with 110 kV redundancy
- Dual electrical redundancy per building
- UPS with 5/4N redundancy, 10-min battery backup
Backup & fuel
- Backup generators — 12 hrs autonomy at full load
- 2 fuel suppliers, 4-hour delivery SLA
- Automatic failover and load-balancing
Fire & security
- Triple-layer fire detection with gas suppression
- Dual redundancy on all suppression systems
- Multi-perimeter access control, 24/7 CCTV
What clients ask us.
What is a private cage?
A dedicated section of the server hall with an enhanced security perimeter. Only your authorized staff can enter — 24/7 — without taking an entire private room.
How does a cage differ from a cabinet or a full room?
A cabinet is one lockable rack (up to 20 kW). A cage is an isolated multi-rack zone with its own perimeter. A dedicated room is a full hall under exclusive client control, including custom engineering.
Is power dedicated to the cage?
Yes. Power delivery is guaranteed for the cage load, on the same campus feeds: two independent 110 kV sources, UPS 5/4N, and 12-hour generator autonomy.
Can we mix standard and non-standard cabinets?
Yes. The cage supports standard and non-standard server cabinets of any size, with flexible layout inside the perimeter.
When will cage colocation be available?
With the first phase in May 2027. Pre-launch pipeline is already 107% of DC-1 capacity. Reservations are discussed with sales.